If you have been reading about detector and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2026-03-31. Where a claim depends on a specific study, the study is described rather than over-claimed.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
| Property | Value | Notes |
|---|---|---|
| Retention time RSD | ≤1% for five replicate injections | Typical criterion; method-specific limits apply. |
| Resolution | ≥1.5 between critical pair | Baseline separation is generally desired. |
| Tailing factor | ≤2.0 | Measures peak symmetry. |
| Theoretical plates | ≥2000 per column | Method-dependent; higher values indicate greater efficiency. |
| Peak area RSD | ≤2% for replicate injections | Reflects autosampler and detector precision. |
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
The Bergmann degradation is a series of chemical reactions designed to remove a single amino acid from the carboxylic acid (C-terminal) end of a peptide. First demonstrated by Max Bergmann in 1934, it is a rarely used method for sequencing peptides. The later developed Edman degradation is an improvement upon the Bergmann degradation, instead cleaving the N-terminal amino acid of peptides to produce a hydantoin containing the desired amino acid. The Bergmann degradation follows the earlier work of Bergmann and his close colleague Leonidas Zervas, combining the organic azide degradation of the Curtius rearrangement with the Bergmann-Zervas carbobenzoxy method, which they designed to occur under relatively mild conditions so as to allow peptide sequencing. A single round of the Bergmann degradation yields an aldehyde containing the sought after amino acid residue and the remaining fragment of the original peptide in amide form.
The food industry is a major consumer of amino acids, especially glutamic acid, which is used as a flavor enhancer, and aspartame (aspartylphenylalanine 1-methyl ester), which is used as an artificial sweetener. Amino acids are sometimes added to food by manufacturers to alleviate symptoms of mineral deficiencies, such as anemia, by improving mineral absorption and reducing negative side effects from inorganic mineral supplementation. Amino acids are low-cost feedstocks used in chiral pool synthesis as enantiomerically pure building blocks. Amino acids are used in the synthesis of some cosmetics. The chelating ability of amino acids is sometimes used in fertilizers to facilitate the delivery of minerals to plants in order to correct mineral deficiencies, such as iron chlorosis. These fertilizers are also used to prevent deficiencies from occurring and to improve the overall health of the plants.
Another common example is the reaction of a primary amine or secondary amine with a carboxylic acid or with a carboxylic acid derivative to form an amide. This reaction is widely used, especially in the synthesis of peptides. On the simple addition of an amine to a carboxylic acid, a salt of the organic acid and base is obtained. To overcome this, the carboxylic acid first needs to be "activated". This is usually done by converting the acid into a more reactive derivative (i.e. anhydride, acid halide) or by using a coupling agent. In some cases, high temperatures (>200 °C) can overcome salt formation by driving off water, without the need for "activation" of the carboxyl group. The downside to this simple reaction is that the compounds may decompose at these elevated temperatures. The carboxylic acid derivatives can be esters, anhydrides, acid halides or any other activated species. The choice of activated carboxyl group or coupling agent can be very important in peptide synthesis, as using the wrong one can lead to racemization.
5-HEDH is an NADPH dehydrogenase oxidoreductase enzyme. It transfers a hydrogen cation (or hydron) H+ from 5(S)-hydroxy (i.e. 5(S)-OH) residues of its fatty acid targets to nicotinamide adenine dinucleotide phosphate+ (NADP+) to form 5-oxo (i.e. 5-O=) counterparts of its targets plus reduced NADP+, i.e. NADPH. The reaction (where R indicates a long chain [14 or more carbons] fatty acid) is: NADP+ + 5(S)-hydroxy fatty acid (i.e. 5(S)-OH-R) ⇌ {\displaystyle \rightleftharpoons } NADPH + H+ + oxo fatty acid (i.e. 5-O=R) The reaction appears to follow a ping-pong mechanism. It is fully reversible, readily converting 5-oxo targets to their corresponding 5(S)-hydroxy counterparts. The direction of this reaction is dependent on the level of NADP+ relative to that of NADPH: The immediate metabolic precursor to 5(S)-HETE, 5(S)-hydroperoxy-6S,8Z,11Z,14Z-eicosatetraenoic acid 5(S)-HpETE, can be converted to 5-oxo-ETE in a non-enzymatic dehydration reaction or chemical lipid peroxidation reactions. The physiological occurrence and relevancy of these reaction pathways has not been ascertained.
Sources: en.wikipedia.org
In botany, apical dominance is the phenomenon whereby the main, central stem of the plant is dominant over (i.e., grows more strongly than) other side stems; on a branch the main stem of the branch is further dominant over its own side twigs. Plant physiology describes apical dominance as the control exerted by the terminal bud (and shoot apex) over the outgrowth of lateral buds.
The above descriptions ignore the effects of Gβγ–signalling, which can also be important, in particular in the case of activated Gαi/o-coupled GPCRs. The primary effectors of Gβγ are various ion channels, such as G-protein-regulated inwardly rectifying K+ channels (GIRKs), P/Q- and N-type voltage-gated Ca2+ channels, as well as some isoforms of AC and PLC, along with some phosphoinositide-3-kinase (PI3K) isoforms.
Mass spectrometry has been successfully used to identify changes in the composition of the adhesome upon perturbation. Schiller et al. as well as Kuo et al. examined the effect of inhibition of myosin contractility on the integrin adhesome composition and found LIM domain proteins and beta-PIX to be tension sensitive. Gou et al. found little change in the cadherin adhesome after calcium depletion from the media, which essentially abrogates cell-cell adhesion. Reinhard Fassler and co-workers used proteomics on specifically engineered cell lines to distinguish between the adhesome of β1- and αv-class integrins.
In plants, nitrogen is first assimilated into organic compounds in the form of glutamate, formed from alpha-ketoglutarate and ammonia in the mitochondrion. For other amino acids, plants use transaminases to move the amino group from glutamate to another alpha-keto acid. For example, aspartate aminotransferase converts glutamate and oxaloacetate to alpha-ketoglutarate and aspartate. Other organisms use transaminases for amino acid synthesis, too. Nonstandard amino acids are usually formed through modifications to standard amino acids. For example, homocysteine is formed through the transsulfuration pathway or by the demethylation of methionine via the intermediate metabolite S-adenosylmethionine, while hydroxyproline is made by a post translational modification of proline. Microorganisms and plants synthesize many uncommon amino acids. For example, some microbes make 2-aminoisobutyric acid and lanthionine, which is a sulfide-bridged derivative of alanine. Both of these amino acids are found in peptidic lantibiotics such as alamethicin. However, in plants, 1-aminocyclopropane-1-carboxylic acid is a small disubstituted cyclic amino acid that is an intermediate in the production of the plant hormone ethylene.
Pharmaceutical engineering is an interdisciplinary science that includes drug engineering, novel drug delivery and targeting, pharmaceutical technology, unit operations of chemical engineering, and pharmaceutical analysis. It may be deemed as a part of pharmacy due to its focus on the use of technology on chemical agents in providing better medicinal treatment. This is an extremely broad category—essentially covering all health care products that do not achieve their intended results through predominantly chemical (e.g., pharmaceuticals) or biological (e.g., vaccines) means, and do not involve metabolism. A medical device is intended for use in: the diagnosis of disease or other conditions in the cure, mitigation, treatment, or prevention of disease. Some examples include pacemakers, infusion pumps, the heart-lung machine, dialysis machines, artificial organs, implants, artificial limbs, corrective lenses, cochlear implants, ocular prosthetics, facial prosthetics, somato prosthetics, and dental implants.
Sources: en.wikipedia.org
Anne Ephrussi (born 15 September 1955 in Paris, France) is a French developmental and molecular biologist. Her research is focused on the study of post-transcriptional regulations such as mRNA localization and translation control in molecular biology as well as the establishment of polarity axes in cell and developmental biology. She is director of the EMBL International Centre for Advanced Training (EICAT) program at the European Molecular Biology Laboratory (EMBL) since 2005 and served as head of the Developmental Biology Unit from 2007 to 2021.
Weapon No. 2, which underwent something other than normal release from the aircraft, evidenced by the fact that the parachute did not deploy, also had its arming rods extracted, and those components which were given the opportunity to act, did act in the manner expected. Full operation of this weapon was prevented by several things: Impact occurred so soon after separation of the Bisch rods that the timers were not given an opportunity to run down. The Arm/Safe Switch was in the "Safe" condition as the weapon left the aircraft. Another analysis by Sandia engineers in 1961 concluded that while in both weapons the MC-772 Arm/Safe Switch operated "as it was designed to do," the lanyard-controlled safing-pins "cannot be relied upon to prevent initiation of the fuzing sequence" in this kind of accident, and recommended implementing a modification to the weapons "as rapidly as possible" that would prevent the fuze power supply from activating except when live release was intended. A 1969 analysis by Sandia supervisor Parker F. Jones concluded that the Goldsboro accident illustrated that "the Mk 39 Mod 2 bomb did not possess adequate safety for the airborne alert role in the B-52."
Biopolymers are natural polymers produced by the cells of living organisms. Like other polymers, biopolymers consist of monomeric units that are covalently bonded in chains to form larger molecules. There are three main classes of biopolymers, classified according to the monomers used and the structure of the biopolymer formed: polynucleotides, polypeptides, and polysaccharides. The polynucleotides, RNA and DNA, are long polymers of nucleotides. Polypeptides include proteins and shorter polymers of amino acids; some major examples include collagen, actin, and fibrin. Polysaccharides are linear or branched chains of sugar carbohydrates; examples include starch, cellulose, and alginate. Other examples of biopolymers include natural rubbers (polymers of isoprene), suberin and lignin (complex polyphenolic polymers), cutin and cutan (complex polymers of long-chain fatty acids), melanin, and polyhydroxyalkanoates (PHAs).
Alloxan is a toxic glucose analogue, which selectively destroys insulin-producing cells in the pancreas (that is, beta cells) when administered to rodents and many other animal species. This causes an insulin-dependent diabetes mellitus (called "alloxan diabetes") in these animals, with characteristics similar to type 1 diabetes in humans. Alloxan is selectively toxic to insulin-producing pancreatic beta cells because it preferentially accumulates in beta cells through uptake via the GLUT2 glucose transporter. Studies suggest alloxan does not cause diabetes in humans. Others found a significant difference in alloxan plasma levels in children with and without type 1 diabetes. Alloxan (C4H2N2O4) readily undergoes redox cycling with its one-electron (C4H3N2O4• semiquinone) and two-electron (dialuric acid, C4H4N2O4) reduction products. In the presence of intracellular reductants such as glutathione (or other thiols), this leads to the generation of toxic reactive oxygen species (ROS) via the interaction of alloxan reduction products with molecular oxygen and related species:
Sources: en.wikipedia.org
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.
Retention time drift can result from changes in mobile phase composition, column temperature, pump flow, or column age. A gradual shift often points to column degradation. A sudden shift may indicate a leak, mixing error, or incorrect mobile phase.
Retention time alone cannot confirm identity because different compounds may elute at similar times. Coupling HPLC with mass spectrometry or comparing against authenticated standards increases confidence. Confirmation usually requires orthogonal data.
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.